call now 01785 254 597

 

pH Probe Range

When it comes to the accurate measurement of pH in an industrial environment, a good quality pH probe is the secret to achieving this.

Firstly, there are a number of different terms applied for a device used to measure pH, we break these down as follows:-

pH Sensor

We use this term to broadly cover any type of device used to measure pH.

pH Electrode

We reserve the term pH probe to mean our glass bodied pH sensors. These can be used to measure pH in some industrial environments, normally if used in conjunction with an inline pH sensor housing. If you're looking for a replacement pH sensor for this type of application then please look at the pH electrode section.

pH Probe

We reserve this term to refer to a pH sensor contained within an industrial housing.

Our pH probes are designed for use in the harshest of industrial environments. Meaning that no element of the pH probe construction has been compromised to ensure both precision measurement, increased longevity and resistance to environmental conditions.

pH Probe Reference

For our industrial pH probe range, we only use an annular reference, also known as a peripheric junction. Where a wick style reference will block or have a reduced flow rate, an annular reference is non-blocking, guaranteeing continuous pH measurement and reducing the requirement to remove the probe for cleaning, which is important to our process critical industrial customers.

The annual reference is also available as a tuff tip to prevent the glass bulb from becoming damaged during calibration or if solids are present in the solution being measured.

We've tried to limit our reference materials to the two most robust types availalbe. One is a pH probe with a ceramic reference, and the other is a pH probe with a PTFE reference. Both are very chemically resistant and offer a non-fouling reference junction to ensure rapid changes in pH value to be monitored.

pH Probe Body

We understand that industrial pH probes are normally kept in process for the duration of their working lives. These are normally either screwed in-place or mounted into a riser tube for insertion into a vessel. As such, our pH probe range all include threaded connections for either or both of these two purposes.

The majority of our pH probes are available in PVC, however, for more harsh industrial environments, these are manufactured in PVDF.

pH Probe Glass

As with our pH electrode range, we have 5 different types of glass that we use. Some are specifically for measuring changes in pH value, others to prevent the leaching of materials in low conductivity solutions. If you have any concerns or require more information about the benefits of our pH glass then please don't hesitate to get in touch.

For our pH probe connections we only use a low impedance specifically shielded pH connecting cable. As standard, we choose to terminate in a BNC process connector, alternatively, we can manufacture tagged ends, spade types, and most electrode connection types. There is some more information on pH sensor connections here and if in doubt - just get in touch!

pH Probe Range


PS183-20B

PS183-20B

Replacement pH probe model PS183-20B

The 3/4" BSP thread is designed to fit as pH probe insert into our PS90S dip mounting pH probe assembly when a replacement is required

Manufactured in PVC, fitted with pH bulb guard and 20 feet of connecting cable terminating in a BNC plug this pH probe is simple and easy to connect to a pH controller

Features an annular non-fouling ceramic reference junction and rated for use from 0-60ºC

View Product


PTT183-20B

PTT183-20B

Tuff Tip pH probe PTT183-20B is a replacement pH probe insert for the PTT90S

With a 3/4" BSP thread is simply screws in place of the redundant pH probe of the PTT90S dip mounting pH probe assembly

Manufactured in PVC, and with a non-fouling ceramic tuff tif magna flow reference with recessed pH bulb this means that the pH bulb is virtually unbreakable during normal operation.

Fitted with 20 feet of connecting cable terminating in a BNC plug this pH probe is simple and easy to connect to a pH controller

Perfect for use in tanks and vessels with an installed mixer and rated for use from 0 - 60ºC

View Product


9027-10B

9027-10B

Inline pH probe model 9027-10B has a 1/2" male thread which is designed for mounting in a tee piece inline so that the pH probe forms part of the pipework.

Single junction pH probe with annual reference junction and exposed pH bulb ensures that pH measurement is precise and the repose time to changing pH values is quick.

Designed for inline mounting into pipework for continual online pH measurement with non-fouling reference the 9027-10B only needs to removed for periodic calibration

Rated for temperature use from 0 - 100ºC and fitted with 10 feet of connecting cable and BNC plug as standard

View Product


P8194-10B

P8194-10B

Our P8194-10B is designed as a tough pH probe with exposed glass pH bulb

The exposed glass bulb gives excellent performance in less than desirable conditions while the pH probe guard is designed to minimise any impact of solids affecting the pH probe integrity

With a non fouling annular ceramic reference this pH probe only needs to be removed from normal operation for periodic calibration or buffering

Fitted with two 3/4" male threads, one mounted at the front and a second at the rear this pH probe can be used in both dip and inline operation

The Kynar (PVDF) body offers excellent chemical compatibility and is rated for use in temperatures from 0 - 100ºC

View Product


P800-T-TC1-10B

P800-T-TC1-10B

The P800-TC1-10B is designed as an industrial pH probe for use when the pH process is critical but the environment is less than desirable

The body is manufactured in Kynar (PVDF) which boasts both excellent temperate and chemical compatibility properties

The non fouling reference junction is our magna flow tuff tip design but constructed from porous PTFE to give expectational pH measurements and response times while maintaining the temperature and chemical compatibility properties from an industrial pH probe

Fitted with dual 3/4" male threads for dip or inline mounting, and with temperature compensation available ex-stock - this is the one pH electrode we recommend our customers hold in stock if their process is pH critical

Rated for temperature usage from 0 - 100ºC

View Product


3637-10B

3637-10B

The P3637-10B is our long life pH probe

With a single rear mounting 3/4" male thread the P3637-10B is specifically designed for use in dip mounting vessels when the pH value is pushing the longevity of existing pH probes

Manufactured to the highest specification the P3637-10B has an extended body, non-fouling annual peripheric junction manufactured in PTFE and a body built from PVDF the temperature and chemical compatibility of the long-life pH probe P3637-10B are unparalleled.

As standard the P3637-10B is fitted with 10 feet of connecting cable and BNC plug as standard and with automatic temperature compensation available ex-stock

The P3637-10B is rated for temperature usage from 0 - 100ºC

View Product

PS183-20B

Replacement pH Probe

replacement ph probe model ps183 750 20b

The PS183-20B is a replacement pH Probe designed to work with our PS90S Dip pH Electrode system.

The probe has a 3/4" BSP mounting thread and is designed with an electrode guard to prevent the glass bulb being compromised from mechanical damage. It has a double junction to resist electrode poisoning and a very fast response time using a free flowing annular ceramic junction.

With the 3/4" BSP thread, it can easily be removed from the dip pH electrode system for calibration or service.

Please note, the PS183-20B was formerly called model number PS183-750-20B; but is now referred to the more straight forward PS183-20B.


Replacement pH Probe model PS183-20B

The PS183-20B replacement pH probe is a double junction, combination pH probe in rugged industrial housing, manufactured in PVC.

The probe has the 3/4" BSP thread at the base so it can easily be screwed into one of our dip assemblies; most commonly the PS90S Submersible pH electrode system.

The PS183-20B construction includes an electrode guard to prevent mechanical damage to the glass bulb, while still allowing excellent contact with the solution to be measured. With a non-fouling annular ceramic junction the response time of the pH probe is excellent and with the non fouling junction it means that this pH sensor has no problems with continual pH measurement.

The PS183-20B is designed as a replacement pH Probe insert for use with the PS90S dip pH electrode assembly. It is designed for mounting in open tanks, pits, sumps or any other non-pressurised vessel. These are commonly mounted within tanks that have dosing pumps, industrial mixers or agitators mounted into them. We would recommend that where an industrial mixer or agitator is present, the liquid to be monitored is reasonably clear of solids or particulates that may damage the glass. In instances where particulate matter is present, we would suggest using our replacement tuff tip pH probe model PTT183-20B.

The PS183-20B is also designed to be resistant to electrode poisoning from solutions which would otherwise react with a silver, silver chloride electrode reference.


Replacement pH Probe Model PS183-20B Features & Benefits

The PS183-20B replacement pH probe with non-fouling annular reference and double junction. This sealed pH probe is designed as a replacement pH probe insert for use with a PS90S dip pH electrode system for submersion in industrial applications that use non-pressurised vessels.

The pH probe has a built in electrode guard to resist against mechanical damage. These probes are frequently mounted in tanks where agitators or industrial mixers are present. This pH electrode is designed for rugged applications and gives precision measurements across the 0-13pH range and is suitable for a temperature range of 0-50°C.

The PS183-20B is supplied with 20 feet of connecting cable as standard and a BNC plug for easy connection to our pH instrument range.

  • Specifications

    Specifications

    PS183-20B

    Replacement pH probe

    Model No:- PS183-20B (Old Part No. PS183-750-20B)

    Range:- 0-13 pH

    Installation:- Single 3/4" BSP Thread

    Mounting:- Submersion

    Housing Material:- PVC

    Junction:- Double Junction

    Reference:- Annular Ceramic

    Operating temperature:- 0-50ºC

  • Ordering Information

    Model NumberCable LengthConnector
    PS183-10B 3 Metres BNC Connector (Most Common)
    PS183-20B 6 Metres BNC Connector (Most Common)
    PS183-30B 9 Metres BNC Connector (Most Common)
    PS183-10T 3 Metres Stripped & Tinned Connections
    PS183-20T 6 Metres Stripped & Tinned Connections
    PS183-30T 9 Metres Stripped & Tinned Connections
    PS183-10A 3 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    PS183-20A 6 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    PS183-30A 9 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    PS183-10I 3 Metres Din 19262 Connector for German pH Instruments
    PS183-20I 6 Metres Din 19262 Connector for German pH Instruments
    PS183-30I 9 Metres Din 19262 Connector for German pH Instruments
    PS183-10K 3 Metres Belling Lee Connector for older U.K. pH Instruments
    PS183-20K 6 Metres Belling Lee Connector for older U.K. pH Instruments
    PS183-30K 9 Metres Belling Lee Connector for older U.K. pH Instruments

    For more information on the connection type please take a look at our pH electrode connection types page.

    Electrodes with a longer cable lengths or custom cable lengths are available to order.

 

PTT183-20B

Tuff Tip pH Probe

tuff tip ph probe model ptt183 20b

The PTT183-20B is a tuff tip pH Probe, designed to fit into the PTT183-20B Dip pH Electrode system.

The probe has a 3/4" BSP mounting thread which makes it easy to install into the PTT90S dip pH probe assembly. Even better, when it comes to removing the pH probe for calibration, it's simply a case of unscrewing the electrode and carrying through the calibration procedure.


Tuff Tip pH Probe PTT183-20B

The tuff tip liquid reference junction is specifically shaped to prevent the pH bulb from breaking. This is especially important when the dip pH probe assembly is installed into tanks and vessels with mixers or agitators present.

The tuff tip also works as a large annular reference junction, meaning that the porous material is always in contact with the solution being measured and the large surface area gives the tuff tip pH probe an excellent response time to shift in the pH value.

As with all the pH probes with the tuff tip reference, the reference junction is non-fouling meaning that you don't need to inspect, clean or replace a pH probe where the reference has fouled.

The tuff tip pH probe PTT183-20B also features a double junction to ensure that it is resistant to electrode poisoning. This is where the solution being measured can react with the silver, silver chloride reference of a single junction pH electrode, causing poor performance, inaccurate readings and eventually electrode failure.


Tuff Tip pH Probe PTT183-20B Features & Benefits

The tuff tip pH probe not only benefits from the large annular reference junction, it also has a recessed pH bulb.  This makes it very difficult for the bulb to break. If the pH electrode were to be pushed onto a flat surface, the pH bulb would not be in contact with the surface. 

The PTT183-20B combines precision pH measurement with a probe designed to withstand difficult mechanical environments.

With a double junction, the PTT183-20B is resistant to electrode poisoning.

The pH probe is also fitted with 20 feet or 6 metres of connecting cable as standard, meaning that installation into a process vessel, tank or other vessel is as simple as possible.

  • Specifications

    Specifications

    PTT183-20B

    Replacement Tuff Tip pH probe

    Model No:- PTT183-20B (Old part no. PTT183-750-20B)

    Range:- 0-13 pH

    Installation:- Single 3/4" BSP Thread

    Mounting:- Submersion

    Housing Material:- PVC

    Junction:- Double Junction

    Reference:- Tuff Tip Magna Flow Liquid Junction

    Operating temperature:- 0-50ºC

  • Ordering Information

    Model NumberCable LengthConnector
    PTT183-10B 3 Metres BNC Connector (Most Common)
    PTT183-20B 6 Metres BNC Connector (Most Common)
    PTT183-30B 9 Metres BNC Connector (Most Common)
    PTT183-10T 3 Metres Stripped & Tinned Connections
    PTT183-20T 6 Metres Stripped & Tinned Connections
    PTT183-30T 9 Metres Stripped & Tinned Connections
    PTT183-10A 3 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    PTT183-20A 6 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    PTT183-30A 9 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    PTT183-10I 3 Metres Din 19262 Connector for German pH Instruments
    PTT183-20I 6 Metres Din 19262 Connector for German pH Instruments
    PTT183-30I 9 Metres Din 19262 Connector for German pH Instruments
    PTT183-10K 3 Metres Belling Lee Connector for older U.K. pH Instruments
    PTT183-20K 6 Metres Belling Lee Connector for older U.K. pH Instruments
    PTT183-30K 9 Metres Belling Lee Connector for older U.K. pH Instruments

    For more information on the connection type please take a look at our pH electrode connection types page.

    Electrodes with a longer cable lengths or custom cable lengths are available to order. 

 

9027-10B

Inline pH Probe

inline ph probe model p9027

The 9027-10B inline pH Probe is designed to be screwed into pipework using it's 1/2" male thread. We recommend using a 1/2" or 3/4" tee piece which will allow the pH probe to give continuous pH measurements.


9027-10B Inline pH Probe

The 9027-10B is fitted as standard with 10 feet of specifically shielded pH cable, terminating in a BNC connection. The pH glass bulb is fully exposed and combines an annular ceramic reference junction, as found in our pH electrode range.

The inline pH probe 9027-10B is fitted with a sealed reference, incorporating our high temperature reference gel, making this pH probe suitable for a temperature range from 0-100ºC.

The silver, silver-chloride (Ag-AgCl) reference combined with the full glass domed bulb and annular ceramic reference junction means that even for continuous online pH measurement, the result is accurate and rapid, in response to changes in pH value.


9027-10B Inline pH Probe Features & Benefits

The 9027-10B is an excellent inline pH probe, designed to be screwed into either a 1/2" or 3/4" Tee piece, using the included 1/2" male thread.

The pH reading is accurate and responsive as a result of the annular ceramic reference and full domed pH bulb even in less than desirable conditions.

The pH probe is fitted with 10 feet of connecting cable making it easy to connect to a suitable pH controller or pH transmitter.

The 1/2" male thread means removing the inline pH probe for periodic calibration is as easy as possible and installation is as simple as screwing the probe into a pipe.

With the sealed gel reference and industrial housing the 9027-10B is suitable for temperatures from 0-100ºC.  

  • Specifications

    Specifications

    9027-10B

    Inline pH probe

    Model No:- 9027-10B

    Range:- 0-13 pH

    Installation:- Single 1/2" Male Thread

    Mounting:- Inline / Online

    Housing Material:- PVC

    Junction:- Single Junction

    Reference:- Non-fouling Peripheric Annular Ceramic

    Operating temperature:- 0-100ºC

    Automatic Temperature Compensation:- Optional

  • Ordering Information

    Model NumberCable LengthConnector
    9027-10B 3 Metres BNC Connector (Most Common)
    9027-20B 6 Metres BNC Connector (Most Common)
    9027-30B 9 Metres BNC Connector (Most Common)
    9027-10T 3 Metres Stripped & Tinned Connections
    9027-20T 6 Metres Stripped & Tinned Connections
    9027-30T 9 Metres Stripped & Tinned Connections

    For more information on the connection type please take a look at our pH electrode connection types page.

    Electrodes with a longer cable lengths or custom cable lengths are available to order. 

 

P8194-10B

P8194-10B Tough pH Probe

tough ph probe model p8027

The P8194-10B is an uncompromised pH probe which despite it's fully exposed pH bulb, is tough and designed for harsh industrial environments.

The P8194-10B has two 3/4" male threads.  One at the front allowing it to be mounted inline with pipework for continuous online pH measurement and the other at the rear, allowing for mounting from a riser tube, to become a dip mounting pH sensor.


P8194-10B Tough pH probe

The P8194-10B is a tough pH probe designed for harsh chemical environments and continual operation whether tank mounted or inline mounted.

The exposed glass pH bulb is protected by a pH guard, so reducing the probability of being compromised by solids in pipework, or under agitation in a vessel with a tank mounted mixer.

The full glass pH bulb and annular reference junction ensure that the response time is rapid to fluctuations in pH value, where process pH has to be held at a specific value or corrected to a pH value. Combined with a double junction for the prevention of electrode poisoning means that this tough pH probe is most commonly found to be used by electroplaters.

The body is manufactured in Kynar (PVDF) for giving this tough pH probe a mechanically strong and chemically resistant outer body. The hexagonal shape of the body makes it possible for this tough pH probe to be tightly screwed into place using a wrench.


P8194-10B Tough pH probe Features & Benefits

With a double junction to prevent electrode poisoning, the probe has a non-fouling annular ceramic reference and an exposed pH bulb. The P8194-10B combines rapid response times and accurate pH measurement with a tough resilience, demanded for process control and measurement within the industry.

Fitted with a 10 ft pH connecting cable and terminating with a BNC connector as standard, the P8194-10B is simple to connect to most pH controllers.

The body is manufactured from chemically resistant and mechanically strong Kynar (PVDF) and with a ceramic non-fouling reference, this tough pH probe can be immersed in some of the harshest environments while maintaining continual and accurate pH measurement.

The wetted parts make the P8194-10B suitable for an operational temperature between 0-100ºC.

  • Specifications

    Specifications

    P8194-10B

    Rugged pH probe

    Model No:- P8194-10B

    Range:- 0-13 pH

    Installation:- Dual 3/4" Male Threads

    Mounting:- Inline / Online / Submersion

    Housing Material:- Kynar (PVDF)

    Junction:- Double Junction

    Reference:- Annular Ceramic with pH bulb guard

    Operating temperature:- 0-100ºC

    Automatic Temperature Compensation:- Optional

  • Ordering Information

    Model NumberCable LengthConnector
    P8027-10B 3 Metres BNC Connector (Most Common)
    P8027-20B 6 Metres BNC Connector (Most Common)
    P8027-30B 9 Metres BNC Connector (Most Common)
    P8027-10T 3 Metres Stripped & Tinned Connections
    P8027-20T 6 Metres Stripped & Tinned Connections
    P8027-30T 9 Metres Stripped & Tinned Connections
    P8027-10A 3 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    P8027-20A 6 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    P8027-30A 9 Metres U.S. Standard Connector fitted to older U.S. pH Instruments
    P8027-10I 3 Metres Din 19262 Connector for German pH Instruments
    P8027-20I 6 Metres Din 19262 Connector for German pH Instruments
    P8027-30I 9 Metres Din 19262 Connector for German pH Instruments
    P8027-10K 3 Metres Belling Lee Connector for older U.K. pH Instruments
    P8027-20K 6 Metres Belling Lee Connector for older U.K. pH Instruments
    P8027-30K 9 Metres Belling Lee Connector for older U.K. pH Instruments

    For more information on the connection type please take a look at our pH electrode connection types page.

    Electrodes with a longer cable lengths or custom cable lengths are available to order.

 